3-PHASE ONLINE UPS TECHNICAL SPECIFICATIONS 10 KVA TO 200 KVA UPS (3 PHASE INPUT & 3 PHASE OUTPUT)

UPS CAPACITY

10 KVA

20 KVA

30 KVA

40 KVA

50 KVA

60 KVA

80 KVA

100 KVA

120 KVA

160 KVA

200 KVA

RECTIFIER
Input Voltage 220VΔ / 380VΔ / 460VΔ, 208VY / 380VY /400VY / 415VY

380 / 400 / 415VAC 3 Phase 4 Wire

Input Range

+/- 20%V

307 – 520V

Input Frequency

50 / 60 Hz +/- 5Hz

50 / 60 Hz +/- 7%

Input Power Factor

0.8

Normal Input Current (Amp)

18

36

54

72

90

108

144

180

216

288

350

Maximum Input Current(Amp)

24

45

68

90

113

136

180

225

270

360

437

Power walk in

0% – 100% : 20 sec

15 – 100%
: 15 sec

Efficiency

99%

Voltage Regulation

1%

Current Limit (Amp)

27

54

81

108

135

162

216

270

324

432

525

Ripple Voltage

0.5%

INVERTER
DC Input Range

285 VDC – 420 VDC

Wave form

SINUSOID/SINEWAVE

Output voltage

380 / 400 / 415 VAC 3 Phase 4 Wire

Output power factor

0.8

Voltage regulation 100% unbalance load

+ / – 1 %

Frequency lock range

45 – 55 Hz / 55 – 65 Hz

Output frequency (Free Running)

50 / 60 Hz + / – 0.1 Hz

Phase Shift Under
100% Unbalance Load

120 % + / – 0.5%

Linear Load

< 2 %

< 5 %

Overload

 

<110%

CONTINUOUS

110 – 125%

15 min

125 – 150%

10 min

> 150%

60 sec

Efficiency (100% Load)

93%

93%

93%

93.5%

93.5%

94%

94.5%

94.5%

95%

95%

95%

Maximum Output
Peak Current(Amp)

43

87

130

174

218

260

348

432

520

693

800

STATIC SWITCH
Voltage Range

173 – 277 VAC (LINE TO NEUTRAL)

Frequency Range

45 – 55 Hz / 55 – 65 Hz

Efficiency

99.5%

TRANSFER TIME:
– Mains -> Inverter

0 ms

– Inverter -> Mains

0 ms

Overload 100%

30 sec

300%

1 sec

Isolation with Output

YES

OVERALL CHARACTERISTICS

Overall Efficiency

90%

OPERATING ENVIRONMENT:
– Temperature

0 – 40ºC ( 32 – 104ºF )

– Humidity

0% – 90% ( NON–CONDENSING )

– Altitude

<1500 M ABOVE SEA LEVEL

Maximum Heat
Dissipation (kw)

0.65

1.3

1.9

2.6

3

3.5

4.6

5.4

6.5

8.7

11.5

Weight  (kg) (no Battery)

270

300

400

480

550

680

820

950

1180

1450

2500

PROTECTIONS:
Short Circuit

RECTIFIER, RESERVE, BYPASS NFB

– Lightning

MOV

– EMC Filter

INPUT & OUTPUT

– Galvanic isolation

BETWEEN INPUT & OUTPUT

Data Display by LCD

YES

INDICATIONS & ALARMS:
– LED,LCD,Buzzer

YES

Dry Contact

YES

Battery Start

YES

BATTERY
Battery Type

TUBULAR/LEAD ACID / VRLA/SMF

No. of Cells

174 / 271

Voltage Range

295 – 410VDC / 285-415VDC

Maximum Charge
Current (ADC)

5

10

15

20

25

30

40

50

60

80

100

Battery Low Voltage

320VDC / 305VDC

Battery Low Stop Voltage

295VDC / 285VDC

Boost Charge

402VDC / 415VDC

Float Charge

390VDC / 410VDC

  1. Due to Continuous R & D, Specifications are subject to change.
  2. Customerised specifications are also available.
  3. Hot standby and Parallel Redundant UPS is also available on request.
Back To Top